Comment: ELECTRICAL <br /> <br />1. Wiring visible at the attic has improper wiring splices and missing electrical junction boxes with covers; correct for best safety. <br /> <br />2. Emergency shut off switches for the central heating / hot water boiler are located at the stairway wall / master bedroom hall wall and on the front of the central heating boiler. Use caution as accidental shut off is possible by location of the switches; consider relocating and / or adding approved guards to allow use in event of need, but providing protection from accidental shut off. <br /> <br />3. The ground fault circuit interrupt [GFCI] type electrical outlet at the first floor bathroom is not adequately secured in the wall opening; secure for best use and safety. Standard electrical outlets at the exterior deck and upper bathrooms are tied into the first floor bathroom GFCI type outlet for proper GFCI protection; the reset is located in the first floor bath GFCI type out